Sign in →

Test Code 0230284 Folate, Serum or Plasma

Methodology

Chemiluminescent microparticle immunoassay (CMIA)
 

Performing Laboratory

Alomere Health Hospital Laboratory

Specimen Requirements

Specimen Type: Serum
Collection Container/Tube:

Preferred:  Gold (gel separator) or Red (plain)

Acceptable:  Plasma, Green top Lithium heparin

Specimen Volume: 2.0 mL

Specimen Minimum Volume: 0.2 mL

Collection Instructions:

1. Protect from light.

2. Allow serum tubes to clot completely. This may take up to 30 minutes.

3. Remove sample from cells by pipetting.

3. Indicate whether serum or plasma.

Reject Due To:

Hemolysis:  1+

Specimen Transport Temperature

Refrigerated

Reference Values

Alinity: 7.0-31.4 ng/mL

Day(s) Test Set Up

Monday through Sunday 

Test Classification and CPT Coding

82746